10
Main Unit Results – The main unit indicates
the beginning of a test by flashing the pair
lights in sequence top to bottom. The cable
is then tested and the results displayed as
follows:
Pair light off – Pair is open. Depending on the
wiring standard, this may be correct.
Pair light on – Pair is wired correctly.
Pair light is flashing – One or more errors were
detected for this pair, as indicated by flashing
error lights.
If there are no flashing lights, the results are
displayed for 2 seconds. If there was an error,
the results are displayed for twice as long.
Remote Unit Results – The remote unit
indicates the beginning of a test by flashing the
pair lights quickly, the order or number of lights
flashed depends on the cable being tested.
The cable is then tested and the results
displayed as follows:
Pair light off – Pair is open or has a fault.
Depending on the wiring standard, this may be
correct.
Pair light on – Pair is wired correctly.
If there are no errors, the results are displayed
for 2 seconds.
Commenti su questo manuale